Safety & Certications 8
XP2i-DP Operation Manual
Safety & Certifications
HAZARDOUS LOCATIONS
Every XP2i-DP pressure gauge includes the following Intrinsic Safety approvals:
II 1G Ex ia IIC T4/T3 Ga
FTZU 12 ATEX 0048X
This product conforms to the following standards:
EN 60079-0 : 2009
| EN 60079-11: 2012 | EN 60079-26: 2007
Ex ia IIC T4/T3 Ga
I
ECEx FTZU 12.0009X
This product conforms to the following standards:
IEC 60079-0 : 2011
| IEC 60079-11: 2011-06 | IEC 60079-26: 2006
!
WARNINGS: The following warnings apply to the XP2i:
•
Do not use the RS-232 connector in hazardous locations.
•
Replace batteries in non-hazardous locations and with approved types only.
•
Do not mix battery types or manufacturers.
•
T4 or T3 Temperature Class is based on selection of approved battery. See Approved Batteries on page 4.
•
Special conditions for safe use:
• The equipment shall not be installed in a location where external conditions are conducive to the buildup of electrostatic charge.
• Because the enclosure of the XP2i and XP2i-DD is made of aluminium, if it is mounted in an area where the use of category 1 G apparatus
is required, it must be installed such that, even in the event of rare incidents, ignition sources due to impact and friction sparks are excluded.
CERTIFICATIONS
The XP2i-DP has been tested and certied to comply with a variety of international standards.
This XP2i-DP complies with the Australian requirements for the C-tick mark.
The instrument was tested against AS/NZS 3584, C-tick EMC/EMI requirements.
C
rystal Engineering declares that the XP2i-DP is in accordance with the ATEX Directive, the Electromagnetic Compatibility Directive, and the Pressure
Equipment Directive per our declaration(s).
This XP2i-DP is approved for use as a portable test instrument for Marine use and complies with Det Norsjke Veritas’ Rules for Classication of Ships,
High Speed & Light Craft, and Oshore Standards.
ATEX
C-tick
Intrinsically Safe and Non-incendive for Hazardous Locations: Class I, Division 1,
Groups A, B, C and D, Temperature Code T4 or T3C.
CSA